At present, large buildings with large buildings have underground parking lots. Due to their large area and low floor height, dense equipment pipelines, no or little natural lighting, they need to provide lighting for a long time, but the garage except for the peak hours of commuting, At other times, the traffic flow is not large. If all the lamps in the garage are on for a long time, it will cause a lot of waste of resources during idle time. In order to achieve the effect of on-demand lighting, many garages now use centralized control of the control system. Although this method can achieve the effect of energy saving, the overall program investment cost is high, and the later operation and maintenance costs are also very high.
C-STAR provides underground garage lighting solutions. The lamps can automatically adjust the brightness according to the activities of cars and people to achieve on-demand lighting. No manual operation is required throughout the process. While ensuring safe lighting, it can also maximize energy saving. Power consumption is safe, convenient and energy-saving.
Fully meet the national illumination requirements:
The national standard "GB50034-2013 Architectural Lighting Design Standard" requires:
The standard value of the reference ground illumination of the public garage is 50Lx;
The current value of garage lighting power density limit is 2.5W / ㎡, and the target value is 2W / ㎡;
The underground garage should automatically adjust the illuminance according to the needs of use.
Lamp layout
The installation height of the integrated lamps, the illuminance of each lamp and the requirements of the national architectural lighting design standards require that an 18W induction fluorescent lamp be installed every 7.2 square meters.
When arranging lights in the garage, in order to reduce the glare when driving, and consider the role of guiding the driving, the long axis of the lights at the lane should be consistent with the direction of the vehicle, and the configuration of the lamps should be aligned with the lane and arranged neatly. The guidance of the lighting is good.
According to the actual needs, the parking space can choose high-low brightness automatic conversion mode or automatic light-off mode to achieve the maximum energy saving effect.
When someone or car enters the induction detection range, the lamp will automatically turn on. When the car or person leaves, it will be delayed for 1 minute, and the lamp will automatically enter the 20% brightness standby state.
When someone or car enters the detection range of the lamp, the lamp will automatically turn on. When the car or person leaves, it will be delayed for 1 minute, and the lamp will automatically turn off and enter the standby state.
And for the renovation of underground garage lighting, C-STAR also provides a contract energy model, which can give a perfect solution when the consumer's budget is insufficient or does not want to take the risk of renovation!